Maintenance and monitoring of chain drives
Maintenance intervals and choice of chain technology
Controlling the chain length
More information about maintenance
Pioneering monitoring of chain drives – iwis CCM
Introduction and customer benefits
Function
Display of elongation status
Design development
Operating conditions
Recommendations for use / application description
Warning function CCM
Limits of using CCM
Product website and product flyer
Product movie
Further expansion stages

What to do?

Cleaning
Detect general condition
Rate lubrication condition
Measure chain length
Check chain tension
Check for damages

There is no all-encompassing applicable formula for calculating the maintenance interval under certain conditions and the maintenance scope.
The different chain applications are too specific.
Practical experience from the application are often the better way to determine the right interval and scope.



Key topic at chain maintenance?
Achieve an optimum lubrication condition of the chain to minimize the wear elongation
poor lubrication manifests itself through increased wear in the chain link and thus connected in the chain wear elongation